S
S
Sergey Chernykh2016-02-12 11:27:34
SIP
Sergey Chernykh, 2016-02-12 11:27:34

Trouble setting up AddPac1100F-C?

Good day dear colleagues!
There was a problem with which I have been at war for a week now.
There is a connection diagram for voice gateways AddPac AP1100F-C and AP100B
a899920543e340f2878950b9480df809.png
According to the scheme:
AP1100F-C picks up a certain number (for example, 5455) on the FXO port, sends it to the AP-100B via the local network,
respectively, from the phone they can call anywhere, within the organization, using department codes or within a department. The exit code to the PBX, for example, 7, is followed by a three-digit subdivision code and a four-digit number. Actually, I can’t cope with setting up gateways for this scheme

Answer the question

In order to leave comments, you need to log in

2 answer(s)
V
Viktor, 2016-02-12
@crasyYoZhik

It's hard to find more documented hardware than Addpac - let's take your config and look at the errors (I hope you're not configuring it from a webcam? )

V
Vladimir, 2016-02-12
@rostel

a standard task for routing by means of the gateways themselves
, a bunch of peers is created according to the number of "divisions" with their own prefixes
in the destination gateways, the prefix is ​​\u200b\u200bcut off and sent to the port