R
R
rizzli2017-06-27 08:51:04
Do it yourself
rizzli, 2017-06-27 08:51:04

How to implement a delay for turning on the refrigerator compressor?

There is a rather strange refrigerator Electrolux ERB34090
. One of the thermostats started to work loudly in it. And there was a feature when the thermostat is triggered, the LCD TV flashes (off / on) (and only the TV set, the monitors do not notice all this).
Turned on the compressor manually after the thermostat tripped, everything is fine. Apparently, the contacts have worn out and parasitic processes occur at the time of operation and start-up of the compressor.
I want to insert between the thermostat and the starting posistor, a turn-on delay timer of 555. But I don’t want to use a mechanical relay, but instead of a relay, use a BTA triac.
Can anyone suggest a circuit 555 + a powerful triac?
Thank you.

Answer the question

In order to leave comments, you need to log in

4 answer(s)
A
Andrey Skorzhinsky, 2017-06-27
@AndyKorg

It is not entirely clear why the thermostat cannot be replaced, but the master is the master. You need to start by finding out the required power of the triac (do not forget to multiply by two for reliability), and connecting it is not a problem - take the same MOC and a selected triac. Be sure to provide a booster and other fire protection. 555 is not needed here. Get a soft start of the motor .

S
sergey smoked, 2017-10-31
@serjon777

I also had a similar situation. I replaced the thermostat and everything started to work like clockwork. If you are interested, I ordered the thermostat here https://lb-total.ru/ Delivered in two days.

K
kkuznecov72, 2018-03-28
@kkuznecov72

A number of electronically controlled refrigerators (Candy, Gorenje, Indesit, Ariston) have an 8-minute delay for turning on the refrigerator. The refrigerator turn-on delay protects the motor-compressor from sudden, short-term switching off and on of the refrigerator's power supply.
To turn on the refrigerator with an 8-minute delay:
1. Set the FREEZER CONTROL knob to the "off" position (turn counterclockwise until it stops).
2. Plug the refrigerator into a socket.
3. Turn the FREEZER CONTROL knob to the middle position so that the green indicator lights up.
4. After 8 minutes, the refrigerator will start working.
If this does not help, then it is better to check with the specialists from Compressor Technologies, they are professional in this matter. Look at klapan-pik.ru for more details .
In general, in old Soviet refrigerators until 1993, contact relays were installed that could start the compressor without a pause, or with a short (up to 1 minute) pause.
And yet, when moving or transporting the refrigerator, you must definitely keep it in an upright position for about 2-3 hours, after which you can connect it. This is necessary so that the compressor oil that has leaked out of the compressor glass back.

K
kayosh, 2019-02-10
@kayosh

Contact these guys: https://lb-total.ru