Answer the question
In order to leave comments, you need to log in
Hdd will live?
Good day, dear ones.
There is a home server, F16. but not the point. It has 5 screws. one of them is Seagate Barracuda 7200.12 for 1 TB.
Here is the latest smart report:
smartctl 5.42 2011-10-20 r3458 [x86_64-linux-3.1.5-6.fc16.x86_64] (local build)
Copyright © 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.12
Device Model: ST31000528AS
Serial Number: 9VP8PEDB
LU WWN Device Id: 5 000c50 02717ec5a
Firmware Version: CC38
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 4
Local Time is: Mon Dec 26 11:00:01 2011 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART STATUS RETURN: incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 634) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 183) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x103f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 117 099 006 Pre-fail Always - 160680946
3 Spin_Up_Time 0x0003 094 094 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 64
5 Reallocated_Sector_Ct 0x0033 058 058 036 Pre-fail Always - 1725
7 Seek_Error_Rate 0x000f 072 060 030 Pre-fail Always - 4311725570
9 Power_On_Hours 0x0032 092 092 000 Old_age Always - 7459
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 32
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
188 Command_Timeout 0x0032 100 100 000 Old_age Always - 1
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
190 Airflow_Temperature_Cel 0x0022 079 051 045 Old_age Always - 21 (Min/Max 10/29)
194 Temperature_Celsius 0x0022 021 049 000 Old_age Always - 21 (0 10 0 0 0)
195 Hardware_ECC_Recovered 0x001a 030 020 000 Old_age Always - 160680946
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 31267361922439
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 4283203444
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 3848296669
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 7294 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Answer the question
In order to leave comments, you need to log in
Definitely dies, I also had such a handsome man.
Important data cannot be trusted, but at least up to 2730 relocations will live and, according to seatools, will be absolutely healthy. Moreover, it reads and writes really well. Then seatools still recognizes it as a warranty.
Well ... he will live a little longer, but if I were you, I would already replace him, I think he will die just copying all the data from him, if there are a lot of them. Already too many errors ...
PS Reallocated_Sector_Ct - this is generally the number of moved sectors, i.e. "bads". The more - the closer death ...
I have all the Seagate screws that grew Reallocated_Sector_Ct died.
Didn't find what you were looking for?
Ask your questionAsk a Question
731 491 924 answers to any question