A
A
Alexey Kukharichev2019-07-31 12:08:29
CCTV
Alexey Kukharichev, 2019-07-31 12:08:29

Trassir swears at camera settings, would you know what?

In general, there are two series of hikvision cameras and a Trassir surveillance server. Exclamation marks appear in tracer settings on some cameras. On the ds-2cd2142fwd-is series, settings higher than device specifications are lit at all, but it does not say which ones. On the ds-2cd2122fwd-is series, it constantly writes needs reboot on two, but reboot does not help. What is happening to him? Camera firmware is up to date.

Answer the question

In order to leave comments, you need to log in

3 answer(s)
S
Sergey, 2019-07-31
@Kuhnya

Try to enable/disable cameras from the tracer interface + change resolutions, quality, accompanied by reloading cameras after changes.
I had this after updating the cameras and the tracer, in different firmware different "templates" are wired.
In general, they have a good TP, they can fix it remotely if you create a ticket

N
Newbie2, 2019-07-31
@Newbie2

Looks like hickeys are buggy. I would try to pick up on RTSP and look at the behavior.

A
Alexey Kukharichev, 2019-08-01
@Kuhnya

Everything turned out. Tried the settings. It turned out that some have 4mp resolution and cif 25fps. Dropping down to 20fps on the substream helped where FHD resolution was set, and dropping down to FHD helped where it was 4mp. Thanks Sergey .

Didn't find what you were looking for?

Ask your question

Ask a Question

731 491 924 answers to any question