p440ar controller. The cache is permanently disabled. What is the reason?
There is a ProLiant DL360 Gen9 server with a p440ar controller on board.
Replaced the battery in the controller.
HP Smart Storage Administrator says the cache is permanently disabled.
Answer the question
In order to leave comments, you need to log in
h17007.www1.hpe.com/docs/iss/shared/gen9/error/Adv...
Exactly reseat - pull out and insert the cache module into place