Answer the question
In order to leave comments, you need to log in
How to restore RAID LSI MegaRAID SAS 9260-4i ?
Hello!
I had a mirror raid.
In smart, I saw that one of the disks was throwing errors.
Decided to replace the drive.
Ruined the raid or it fell apart because of the disk.
I beg you to help me build a raid!
How it was before my actions:
# megacli -CfgDsply -aALL
==============================================================================
Adapter: 0
Product Name: LSI MegaRAID SAS 9260-4i
Memory: 512MB
BBU: Absent
Serial No: SV22116973
==============================================================================
Number of DISK GROUPS: 1
DISK GROUP: 0
Number of Spans: 1
SPAN: 0
Span Reference: 0x00
Number of PDs: 2
Number of VDs: 1
Number of dedicated Hotspares: 0
Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name :
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
Size : 2.728 TB
Sector Size : 512
Mirror Data : 2.728 TB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 2
Span Depth : 1
Default Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Disk's Default
Encryption Type : None
Is VD Cached: Yes
Cache Cade Type : Read Only
Physical Disk Information:
Physical Disk: 0
Enclosure Device ID: 252
Slot Number: 1
Drive's position: DiskGroup: 0, Span: 0, Arm: 0
Enclosure position: N/A
Device Id: 4
WWN: 5000c5006035c489
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SATA
Raw Size: 2.728 TB [0x15d50a3b0 Sectors]
Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors]
Coerced Size: 2.728 TB [0x15d400000 Sectors]
Sector Size: 0
Firmware state: Online, Spun Up
Device Firmware Level: CC46
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x4433221102000000
Connected Port Number: 0(path0)
Inquiry Data: W1F2LX05ST3000DM001-1CH166 CC46
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive: Not Certified
Drive Temperature : N/A
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Drive's NCQ setting : N/A
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Drive has flagged a S.M.A.R.T alert : No
Physical Disk: 1
Enclosure Device ID: 252
Slot Number: 0
Drive's position: DiskGroup: 0, Span: 0, Arm: 1
Enclosure position: N/A
Device Id: 5
WWN: 5000c5004d8656ca
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SATA
Raw Size: 2.728 TB [0x15d50a3b0 Sectors]
Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors]
Coerced Size: 2.728 TB [0x15d400000 Sectors]
Sector Size: 0
Firmware state: Online, Spun Up
Device Firmware Level: CC4B
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x4433221103000000
Connected Port Number: 1(path0)
Inquiry Data: Z1F0PXKYST3000DM001-9YN166 CC4B
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive: Not Certified
Drive Temperature : N/A
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Drive's NCQ setting : N/A
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Drive has flagged a S.M.A.R.T alert : No
Exit Code: 0x00
[email protected] ~ # megacli -PDOffline -PhysDrv [252:0] -a0
Adapter: 0: EnclId-252 SlotId-0 state changed to OffLine.
Exit Code: 0x00
[email protected] ~ #
State : Degraded
...
Firmware state: Offline
[email protected] ~ # megacli -PDMarkMissing -PhysDrv [252:0] -a0
EnclId-252 SlotId-0 is marked Missing.
Exit Code: 0x00
[email protected] ~ # megacli -PdPrpRmv -PhysDrv [252:0] -a0
Prepare for removal Success
Exit Code: 0x00
[email protected] ~ #
[email protected] ~ # megacli -CfgDsply -a0
==============================================================================
Adapter: 0
Product Name: LSI MegaRAID SAS 9260-4i
Memory: 512MB
BBU: Absent
Serial No: SV22116973
==============================================================================
Number of DISK GROUPS: 0
Exit Code: 0x00
[email protected] ~ # megacli -LDInfo -Lall -Aall
Adapter 0 -- Virtual Drive Information:
Adapter 0: No Virtual Drive Configured.
Exit Code: 0x00
[email protected] ~ #
Answer the question
In order to leave comments, you need to log in
Why did not they use the office. dock?
Are you sure you replaced the correct drive? It's very strange that vd is gone)
First, make a copy of the disk :)
Show:
MegaCli –LDInfo -Lall -aALL
MegaCli --PDList -aALL
MegaCli –CfgForeign –Scan -aALL
MegaCli –CfgForeign –Preview -aALL
Didn't find what you were looking for?
Ask your questionAsk a Question