I
I
Ivan2016-07-07 09:20:08
Solid State Drives
Ivan, 2016-07-07 09:20:08

How to find smart errors on adaptec 6805 controller?

Smarts appeared on one of the devices:

Device #1
         Device is a Hard drive
         State                              : Online
         Supported                          : Yes
         Transfer Speed                     : SATA 6.0 Gb/s
         Reported Channel,Device(T:L)       : 0,3(3:0)
         Reported Location                  : Connector 0, Device 3
         Vendor                             : 
         Model                              : OCZ-VERTEX3
         Firmware                           : 2.15
         Serial number                      : OCZ-OD6CW0NF4WP483CL
         Size                               : 228936 MB
         Write Cache                        : Enabled (write-back)
         FRU                                : None
         S.M.A.R.T.                         : Yes
         S.M.A.R.T. warnings                : 2
         Power State                        : Full rpm
         Supported Power States             : Full rpm,Powered off,Reduced rpm
         NCQ status                         : Enabled

Script:
echo %date% >> 192.168.1.237.txt
arcconf setvmcredential 192.168.1.237 5989 root password
arcconf getsmartstats 1 >> 192.168.1.237.txt
pause

The output is this:
CIM Exception: *** Provider arc_cli::arcCLIProvider(8058151) exiting due to a SIGSEGV signal.

I do not understand why it is not possible to deliver the signal.
You may need to update the Provider for esxi.

Answer the question

In order to leave comments, you need to log in

Didn't find what you were looking for?

Ask your question

Ask a Question

731 491 924 answers to any question