How to disable Green Power mode in UPS PowerWalker VI 850 SE?

Hello! I recently purchased a PowerWalker VI 850 SE uninterruptible power supply, and unexpectedly for me it turned out that it has a Green Power function - shutdown after 5 minutes at low load, a load of 6% of power turned out to be low for it, although it was purchased specifically for this - to power electronic clock so that when the light is turned off it does not go astray.
Googling, I found a solution for some models - I had to bite the R15A resistor ( korsart.livejournal.com/81138.html), but, unfortunately, I did not find this in my model. I tried to look for a description or diagram of the board by the numbers on it - also no result. Maybe someone has ideas in which direction you can still dig, otherwise I no longer have options :(.
PS. I considered the option with an additional load, but you yourself understand that this is not a solution to the problem.
ISSUE CLOSED, SOLUTION FOUND (Break out a small rectangular resistor R43 from the back of the board)
Attached photos of the board
4af1aab6233b4ea096e323c2fb89d4bc.jpga3cc8ab391f64e1781b8baa6ffb9ac5b.jpg10f1286173374f0ebd1fb4a1390f6ecf.jpg

Answer the question

In order to leave comments, you need to log in

1 answer(s)
V
Voron05, 2018-09-03
@Voron05

It’s not clear where you soldered this resistor R43 from, although you would mark this place with a marker!