Answer the question
In order to leave comments, you need to log in
How long will the disc last?
The disk suddenly fell off, I decided to check it, but I don’t know how to use smart logs. How much more does he have left?
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda Green (AF)
Device Model: ST2000DL003-9VT166
Serial Number: 5YD5XGNH
LU WWN Device Id: 5 000c50 044179389
Firmware Version: CC32
User Capacity: 2 000 398 934 016 bytes [2,00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5900 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Wed Apr 02 07:27:18 2014
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 623) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off supp
ort.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 349) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x30b7) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_
FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 099 099 006 Pre-fail Always -
2569400
3 Spin_Up_Time 0x0003 092 092 000 Pre-fail Always -
0
4 Start_Stop_Count 0x0032 098 098 020 Old_age Always -
2178
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always -
592
7 Seek_Error_Rate 0x000f 058 055 030 Pre-fail Always -
133167100063
9 Power_On_Hours 0x0032 089 089 000 Old_age Always -
10244
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always -
0
12 Power_Cycle_Count 0x0032 099 099 020 Old_age Always -
1574
183 Runtime_Bad_Block 0x0032 096 096 000 Old_age Always -
4
184 End-to-End_Error 0x0032 100 100 099 Old_age Always -
0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always -
0
188 Command_Timeout 0x0032 100 099 000 Old_age Always -
1
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always -
0
190 Airflow_Temperature_Cel 0x0022 056 049 045 Old_age Always -
44 (Min/Max 40/44)
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always -
0
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always -
154
193 Load_Cycle_Count 0x0032 099 099 000 Old_age Always -
2379
194 Temperature_Celsius 0x0022 044 051 000 Old_age Always -
44 (0 20 0 0 0)
195 Hardware_ECC_Recovered 0x001a 023 006 000 Old_age Always -
2569400
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always -
0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline -
0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always -
0
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline -
116771570854119
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline -
3983272616
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline -
1097426226
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Answer the question
In order to leave comments, you need to log in
Reallocated_Sector_Ct is 592 which is pretty bad. I would not say that it will fail very soon, but be sure to make backups.
Didn't find what you were looking for?
Ask your questionAsk a Question