Dell PowerEdge R620 + PERC H310: How do I find the model of installed drives?

Hello. There is a server (even three). Each of them has Proxmox on a RAID-1 of 2*HDD. On one of the servers, the disk fell out of the raid:
5bdbe9e7c3246941791346.png
It would be necessary to replace it. And in order to replace - you need to purchase a replacement. But: there is no way to pull out the disk to look, and in iDrac I don’t see the model. Is there a way to find this model somewhere?

Answer the question

In order to leave comments, you need to log in

2 answer(s)
Z
Zettabyte, 2018-11-03
@Zettabyte

Try looking at R.tester:
https://rlab.ru/tools/rtester.html
R.tester works directly through device drivers, and we specially develop it, incl. and as a program for monitoring and diagnosing hard drives and SSDs installed in various arrays and storages: RAID, NAS and SAN (SAN).
Already, the utility is able to work through many controllers and "bridges", I wonder how it will work on your server.

A
azarij, 2018-11-02
@azarij

What if you press the plus button? what is there?
if the server can be rebooted, then you can get into the bios of the controller and look there.
You can put OMSA on the server and see it there.

Didn't find what you were looking for?