Hello! I have a Dell PowerEdge R815 with Ubuntu Server. It contains RAID1 for the system and RAID1 for data. Today I received a message that one of the system disks "fell" from the raid:
# /usr/sbin/megaclisas-status
-- Controller information --
-- ID | H/W Model | RAM | Temp | BBU | Firmware
c0 | PERC H700 Integrated | 512MB | N/A | REPL | FW: 12.10.1-0001
-- Array information --
-- ID | Type | Size | Strpsz | Flags | DskCache | Status | OS Path | CacheCade |InProgress
c0u0 | RAID-1 | 68G | 64 KB | ADRA,WT | Default | Degraded | /dev/sda | Type : Read Only |None
c0u1 | RAID-1 | 186G | 64 KB | ADRA,WT | Default | Optimal | /dev/sdb | None |None
-- Disk information --
-- ID | Type | Drive Model | Size | Status | Speed | Temp | Slot ID | LSI ID
c0u0p0 | HDD | HP DG072BABCE HPD5BSA5P8400NAW | 67. Gb | Failed | 3.0Gb/s | 29C | [32:0] | 0
c0u0p1 | HDD | HP DG072BABCE HPD6BSA5P8400PPF | 67. Gb | Online, Spun Up | 3.0Gb/s | 27C | [32:1] | 1
c0u1p0 | SSD | BTHV71300B4L200MGN INTEL SSDSC2BA200G4 G2010150 | 185. Gb | Online, Spun Up | 6.0Gb/s | N/A | [32:2] | 2
c0u1p1 | SSD | BTHV71300ANT200MGN INTEL SSDSC2BA200G4 G2010150 | 185. Gb | Online, Spun Up | 6.0Gb/s | N/A | [32:3] | 3
Answer the question
In order to leave comments, you need to log in
1) The error indicator will be lit on the basket of the failed disk, do not mix it up
2) Within a couple of minutes, the rebuild should start by itself.