A
A
alovanton2015-09-04 20:25:22
VMware
alovanton, 2015-09-04 20:25:22

Raid 1, rebuilding, it's been about an hour, what should I do?

Good afternoon. Produced installation of disks in the server. I accidentally touched the cord going to the disk, after that I booted up and saw that the raid was damaged. I turned it off and found where the cord was not connected and turned on the server. There was a mirror there. After 2 hours I go into the array raid log and see:

Logical device information
----------------------------------------------------------------------
Logical device number 0
   Logical device name                      : base
   RAID level                               : 1
   Status of logical device                 : Degraded
   Size                                     : 244090 MB
   Read-cache setting                       : Enabled
   Read-cache status                        : On
   Write-cache setting                      : On when protected by battery/ZMM
   Write-cache status                       : On
   Partitioned                              : Yes
   Protected by Hot-Spare                   : No
   Bootable                                 : Yes
   Failed stripes                           : No
   Power settings                           : Disabled
   --------------------------------------------------------
   Logical device segment information
   --------------------------------------------------------
   Segment 0                                : Present (Controller:1,Connector:0,Device:1) P02309105435
   Segment 1                                : Rebuilding (Controller:1,Connector:0,Device:0) P02309105440
----------------------------------------------------------------------
Physical Device information
----------------------------------------------------------------------
      Device #0
         Device is a Hard drive
         State                              : Rebuilding
         Supported                          : Yes
         Transfer Speed                     : SATA 6.0 Gb/s
         Reported Channel,Device(T:L)       : 0,0(0:0)
         Reported Location                  : Connector 0, Device 0
         Vendor                             : PLEXTOR
         Model                              : PX-256M5S
         Firmware                           : 1.03
         Serial number                      : P02309105440
         Reserved Size                      : 100632 KB
         Used Size                          : 244100 MB
         Unused Size                        : 64 KB
         Total Size                         : 244198 MB
         Write Cache                        : Enabled (write-back)
         FRU                                : None
         S.M.A.R.T.                         : No
         S.M.A.R.T. warnings                : 0
         Power State                        : Full rpm
         Supported Power States             : Full rpm,Powered off
         SSD                                : Yes
         NCQ status                         : Enabled

This is what I saw on ESXI 5.5
8924a9fd7af84c96a8344173b7e685f5.JPG
I would be grateful for any help, thanks!

Answer the question

In order to leave comments, you need to log in

1 answer(s)
R
Ruslan Fedoseev, 2015-09-04
@martin74ua

wait. an hour is not much ;)
I decided to remake the 6th raid on the 5th one on the adapter with 8 screws... the rebuild has been going on for the third year ;)

Didn't find what you were looking for?

Ask your question

Ask a Question

731 491 924 answers to any question