If w32tm does not change the update source, what should I do?

There is a domain controller on Windows Server 2012r2, I can not configure w32tm. I have already tried to configure both through w32tm / config, and through the registry, and through third-party graphic software.
Whatever sources I specify the source value: Local CMOS Clock, when I try to do / resync - Synchronization failed because there is no time data available.
w32tm /query /status
Noise indicator: 0 (no warnings)
Strat: 1 (master link - clocked by radio)
Accuracy: -6 (15.625ms per clock tick)
Root delay: 0.0000000s
Root variance: 10.0000000s Timebase
ID: 0x4C4F434C (source name: "LOCL")
Last successful sync time: 01/31/2017 10:50:13 AM
Source: Local CMOS Clock
Polling interval: 6 (64s)
HKLM\System\CurrentControlSet\services\W32Time\Parameters\Type - NTP
HKLM\System\CurrentControlSet\services\W32Time\Parameters\Ntp - time.windows.com,0x1 au. pool.ntp.org,0x1 time.nist.gov,0x1
What am I doing wrong and how can I fix it?

Answer the question

In order to leave comments, you need to log in

2 answer(s)
S
sflyer, 2017-02-01
@sflyer

Проблема найдена, sfc /scannow пометил несколько файлов как поврежденные, после проверки и замены всё работает отлично.

Константин Цветков, 2017-01-31
@tsklab

Имеется контроллер домена на Windows Server 2012r2, не могу настроить w32tm.
А не надо было ломать. Контроллер домена и так является сервером NTP для остальных компьютеров. Естественно DNS АД должен быть правильно настроен.