D
D
Denis Kurbatov2016-01-19 16:48:29
System administration
Denis Kurbatov, 2016-01-19 16:48:29

How to set VLAN during BMR recovery in EMC Networker?

It is necessary to perform a Bare Metal Recovery of the server using the EMC Networker boot disk.
The problem is that after loading, selecting 1 of 2 network cards and setting network settings for it, there is no access to the network, there is no ping to the gateway. This is most likely due to the fact that network access for the machine is configured through a specific trunk (tagged) VLAN.
How do I set it on the EMC Networker WinPE boot disk?
The Internet has gone through everything. It seems that no one has ever encountered this banal problem before me - it's strange.

Answer the question

In order to leave comments, you need to log in

1 answer(s)
D
Denis Kurbatov, 2016-01-20
@31415

So far, I've settled on the fact that I'm throwing a utility from the NIC manufacturer through the floppy disk image onto the machine. It allows you to make some NIC settings on the command line, in particular, specify the VLAN. A crutch, I think, but Windows is already a big crutch, so one more, one less ...
In fact, the port can be temporarily transferred to access on the same cisco, but this is inconvenient because a specially dedicated person is needed for this - according to the regulations.
And the fact that on the SERVER OS it is impossible to configure VLANs in the standard network stack - I don’t even know what to call it. In 2012+ it is already possible, but there are also nuances.

Didn't find what you were looking for?

Ask your question

Ask a Question

731 491 924 answers to any question