N
N
Nikolai Kostromin2022-03-14 17:35:34
Zabbix
Nikolai Kostromin, 2022-03-14 17:35:34

How to disable the Link down event on switches in Zabbix?

Hello!

In Zabbix 5.0.17, I use the regular Template Net HP Enterprise Switch SNMP template to monitor HP 1920-48G switches. Link down messages constantly appear when the equipment is turned off. How can I disable this check in the template? I understand that somewhere in the triggers it is necessary to look, but I did not find it ....

Answer the question

In order to leave comments, you need to log in

2 answer(s)
K
kisaa, 2022-03-15
@Velobos

Search in direction

Template - Discovery rules - Network Interfaces Discovery - Trigger prototypes
:
pmuytwdt8nna8tqz80vylgdgjja.png
PS You may need to re-create the host switch in order for autodiscovery to work again.

K
ky0, 2022-03-14
@ky0

I think it's worth making these triggers dependent on some common one, like "The device was recently rebooted" or "The device is not available". Then, during reboots, link triggers will not be activated.