smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.16.0-30-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: HGST HTS545050A7E680
Serial Number: TMA55C4T2WSSWL
LU WWN Device Id: 5 000cca 7aae8ce42
Firmware Version: GG2OAF10
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Jun 26 23:09:17 2015 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 45) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 114) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 075 075 062 Pre-fail Always - 111477163
2 Throughput_Performance 0x0005 100 100 040 Pre-fail Offline - 0
3 Spin_Up_Time 0x0007 253 253 033 Pre-fail Always - 0
4 Start_Stop_Count 0x0012 098 098 000 Old_age Always - 4592
5 Reallocated_Sector_Ct 0x0033 069 069 005 Pre-fail Always - 0
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
8 Seek_Time_Performance 0x0005 100 100 040 Pre-fail Offline - 0
9 Power_On_Hours 0x0012 096 096 000 Old_age Always - 1919
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 098 098 000 Old_age Always - 3640
191 G-Sense_Error_Rate 0x000a 100 100 000 Old_age Always - 65536
192 Power-Off_Retract_Count 0x0032 099 099 000 Old_age Always - 217
193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 8725
194 Temperature_Celsius 0x0002 181 181 000 Old_age Always - 33 (Min/Max 5/51)
196 Reallocated_Event_Count 0x0032 058 058 000 Old_age Always - 1164
197 Current_Pending_Sector 0x0022 001 001 000 Old_age Always - 3792
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
223 Load_Retry_Count 0x000a 100 100 000 Old_age Always - 0
SMART Error Log Version: 1
ATA Error Count: 3496 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 3496 occurred at disk power-on lifetime: 1919 hours (79 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 00 00 00 00 Error: UNC at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 08 70 00 00 00 40 00 00:10:44.966 READ FPDMA QUEUED
ef 10 02 00 00 00 a0 00 00:10:44.965 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 e0 00 00:10:44.965 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 00 00:10:44.964 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 00 00:10:44.964 SET FEATURES [Set transfer mode]
Error 3495 occurred at disk power-on lifetime: 1919 hours (79 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 00 00 00 00 Error: UNC at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 08 68 00 00 00 40 00 00:10:41.442 READ FPDMA QUEUED
ef 10 02 00 00 00 a0 00 00:10:41.441 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 e0 00 00:10:41.441 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 00 00:10:41.440 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 00 00:10:41.440 SET FEATURES [Set transfer mode]
Error 3494 occurred at disk power-on lifetime: 1919 hours (79 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 00 00 00 00 Error: UNC at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 08 60 00 00 00 40 00 00:10:37.910 READ FPDMA QUEUED
ef 10 02 00 00 00 a0 00 00:10:37.909 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 e0 00 00:10:37.909 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 00 00:10:37.908 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 00 00:10:37.908 SET FEATURES [Set transfer mode]
Error 3493 occurred at disk power-on lifetime: 1919 hours (79 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 00 00 00 00 Error: UNC at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 08 58 00 00 00 40 00 00:10:34.386 READ FPDMA QUEUED
ef 10 02 00 00 00 a0 00 00:10:34.386 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 e0 00 00:10:34.385 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 00 00:10:34.384 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 00 00:10:34.384 SET FEATURES [Set transfer mode]
Error 3492 occurred at disk power-on lifetime: 1919 hours (79 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 00 00 00 00 Error: UNC at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 08 50 00 00 00 40 00 00:10:30.854 READ FPDMA QUEUED
ef 10 02 00 00 00 a0 00 00:10:30.854 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 e0 00 00:10:30.853 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 00 00:10:30.852 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 00 00:10:30.852 SET FEATURES [Set transfer mode]
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Answer the question
In order to leave comments, you need to log in
About 3 weeks ago, I stumbled about charging the laptop and dropped it, the hard drive came to an end, and with it all the data, very important. It just showed the size of the disk in the BIOS and that's it, the head did not read anything. A lot of work was done, the local master did not console with hopes for data recovery, as a result, he sent it to the data recovery laboratory. Everything you need is fixed at a reasonable price. I don’t know what these numbers mean to you, but I’m sure it’s worth contacting specialists, perhaps not everything is lost, if the data is of course important to you.